Transformer Tandelta Testing Service
Transformer Tandelta Testing Service

Transformer Tandelta Testing Service

Transformer Tandelta Testing Service Specification

  • Measuring Range
  • Tan Delta: 1 x 10 to 1
  • Temperature
  • Operating range -10C to +50C
  • Size
  • Portable unit, Handheld configuration
  • Interface
  • Touchscreen Display with USB and Ethernet connectivity
  • Voltage
  • Test Voltage up to 12 kV AC
  • Driven Type
  • Electric Powered
  • Display
  • High-resolution digital LCD display
  • Usage & Applications
  • Transformer insulation diagnostics, On-site commissioning, Condition monitoring
  • Frequency
  • 50 Hz / 60 Hz selectable
  • Material
  • Digital Testing Equipment with Insulated Probes and Cables
  • Weight
  • Approx. 10-15 kg
  • Power
  • 220-240V AC, 50/60Hz
  • Accessories
  • Test leads, Ground cable, Carrying case included
  • Accuracy
  • 1% of reading
  • Cooling
  • Passive air cooling system
  • Test Duration
  • Programmable, typically 2-10 minutes per phase
  • Safety Standards
  • IEC 60270, IEC 60076-3 compliant
  • Environmental Protection
  • IP54 protection for field work
  • Calibration
  • Factory calibrated, Calibration certificate provided
  • Alarm/Warning
  • Overvoltage and Fault Indication
  • Test Modes
  • Automatic, Manual, Step mode selection
  • Recording Capability
  • Built-in data storage and report generation
 

Transformer Tandelta Testing Service Trade Information

  • Main Domestic Market
  • All India
 

Transformer Tandelta Testing Service About



Transformer Tandelta Testing Service stands as a hot-selling masterpiece for transformer insulation diagnostics, on-site commissioning, and precision condition monitoring across India. With instant checkout and a perfect blend of classic accuracy (1% of reading), compliance to IEC 60270 and IEC 60076-3 safety standards, and programmable test durations (2-10 minutes per phase), this portable, handheld unit is a proven performer. Utilise offer benefits-automatic/manual/step mode selection, built-in data recording, overvoltage protection, and passive air cooling. Featuring high-resolution LCD display, touchscreen interface, IP54 protection, and accessories included, it's the ideal solution for superior transformer reliability assessments.

Usage & Direction: Transformer Tandelta Testing Service

Used for precise insulation diagnostics, this testing service is suitable for on-site commissioning and regular condition monitoring of transformers. Users benefit from a simple touch-screen interface, programmable test durations, and selectable test modes. To use, connect the insulated probes and cables, select parameters, and execute tests with automatic or manual options. Its portable handheld design ensures hassle-free operation for field technicians, making it the perfect choice for effective transformer evaluation.


Sample Policy & Payment Terms: Transformer Tandelta Testing Service

The sample policy aligns with industry standards, offering trial demonstrations as part of our commitment to market value. Payment terms include advance payments and flexible options based on asking price and list price. Services are provided at competitive rates, with FOB Port arrangements available across major Indian ports. Customers can request detailed quotations, ensuring clarity on costs and terms before finalising their purchase to optimise investment value.


FAQ's of Transformer Tandelta Testing Service:


Q: How is the accuracy of the Transformer Tandelta Testing Service achieved and maintained?

A: Accuracy is ensured through factory calibration and accompanied by a calibration certificate. Regular recalibration as per maintenance protocols helps keep measurements within the 1% accuracy range.

Q: What types of transformers can be tested using this service?

A: The service is versatile and suitable for most power and distribution transformers requiring insulation diagnostics, supporting on-site commissioning and ongoing condition monitoring.

Q: When is the ideal time to perform Transformer Tandelta Testing?

A: Testing is recommended during transformer commissioning, after maintenance, and scheduled condition monitoring. Early diagnostics can prevent failures and optimise performance.

Q: Where can the Transformer Tandelta Testing Service be conducted?

A: Thanks to its portable, IP54-rated handheld unit, testing can be performed in field conditions, substations, and industrial sites across India under varying environmental conditions.

Q: What is the process for operating the testing equipment?

A: Connect the insulated probes and cables, set the parameters using the touchscreen interface, choose the test mode (automatic, manual, or step), and start the test. Data is stored internally, and reports are generated efficiently.

Q: What benefits does this service offer over traditional transformer testing methods?

A: It provides faster, programmable test durations, improved accuracy, automatic data recording, reliable safety standards, and enhanced portability for field work, making it more efficient and user-friendly than conventional methods.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing Service Category

Relay Panel Testing Work

Relay Panel Testing Work

Voltage : 110230V AC, 50Hz/60Hz

Temperature : Operating: 10C to +55C

Interface : Human Machine Interface (HMI), Manual control panel, Ethernet/RS485

Size : Custom Panel Size, Standard: 800mm x 600mm x 2200mm (H x D x W)

Power : 3 kW

Weight : Approx. 120180 kg (depends on configuration)

Solar Panel Testing Service

Solar Panel Testing Service

Voltage : Suitable for panels up to 1000 V DC

Temperature : Operating range: 10C to 50C

Interface : Digital and Analog Interface options

Size : Customizable as per panel dimensions

Power : Requires external power supply, AC 220V

Weight : Lightweight, Portable Service Equipment

Electrical Testing Service

Electrical Testing Service

Voltage : Up to 1000V AC/DC

Temperature : Operating range: 0C to 50C

Interface : Manual and digital interfaces available

Size : Standard or customized as per requirement

Power : Electric powered, typically 220V

Weight : Varies with equipment and testing type

Numerical Relay Testing Service

Numerical Relay Testing Service

Voltage : 110230 V AC

Temperature : 050C

Interface : Digital, USB, Ethernet

Size : Standard/Custom

Power : 50150 W

Weight : 25 Kilograms



SSS ELECTRICAL POWER PRIVATE LIMITED
GST : 09ABGCS3246N1ZT
House No-655a/5/p-043a, Unity City Chauraha, Phool Bagh Colony,Lucknow - 226022, Uttar Pradesh, India
Phone :07317168921
Mr Nasir Ali (Director)
Mobile :07317168921